/* nursingwritersbureau.com theme functions */ /* nursingwritersbureau.com theme functions */ {"id":4011,"date":"2020-08-19T08:57:05","date_gmt":"2020-08-19T08:57:05","guid":{"rendered":"https:\/\/nursingwritersbureau.com\/?p=4011"},"modified":"2020-08-19T08:57:05","modified_gmt":"2020-08-19T08:57:05","slug":"for-the-following-research-paper-assignment-you-have-been-asked-to-perform-an-evaluation-of-employee-exposures-at-a-small-automobile-parts-manufacturing-facility","status":"publish","type":"post","link":"https:\/\/nursingwritersbureau.com\/for-the-following-research-paper-assignment-you-have-been-asked-to-perform-an-evaluation-of-employee-exposures-at-a-small-automobile-parts-manufacturing-facility\/","title":{"rendered":"For the following research paper assignment, you have been asked to perform an evaluation of employee exposures at a small automobile parts manufacturing facility."},"content":{"rendered":"
For the following research paper assignment, you have been asked to perform an evaluation of employee exposures at a small automobile parts manufacturing facility. The manufacturing processes include two metal presses, two machining stations, three welding stations, a small paint booth, and a shipping\/receiving area. There are two employees working at each press, one person working at each machining station, one person working at each welding station, two people working in the paint booth, and four employees working in the shipping\/receiving area.<\/p>\n
One of the presses is a 2,000-ton press, and the other press is a 200-ton press. The 2,000-ton press is the greatest noise source for the facility. The machining area uses a metal working fluid. The safety data sheet (SDS) for the metal working fluid is attached here. All welding is performed on stainless steel. The painting booth uses a powder coating operation, but the employees use xylene and methyl ethyl ketone (MEK) to clean the parts prior to the powder coating operation. At the end of the shift, one of the employees uses 1,3 butadiene to clean the nozzles for the paint booth. The facility uses two electric forklifts to move materials between the production area and the storage warehouse and between the warehouse and the shipping area. All employees work an 8-hour shift.<\/p>\n
Part 1:<\/p>\n
Using the information on anticipation and control we studied in the textbook, identify the hazards that are present in the facility. In your discussion, explain why you chose the hazards, and describe whether you believe the hazards to be actual hazards or potential hazards (which require further evaluation). Describe the specific location(s) at the facility where the hazards are located, and determine how many employees are potentially at risk in those areas.<\/p>\n
Your response for Part 1 should be at least one page in length.<\/p>\n
Part 2:<\/p>\n
Using the information on evaluation that we studied in the textbook, summarize how you would measure the personal exposures to the hazards that you identified in Part 1. Use the Occupational Safety and Health Administration (OSHA) website (https:\/\/www.osha.gov\/dts\/sltc\/methods\/toc.html) or the National Institute for Occupational Safety and Health (NIOSH) website (http:\/\/www.cdc.gov\/niosh\/docs\/2003-154\/default.html) to select the specific sampling and analytical method that would work best to evaluate any chemical hazards you identified. Provide a summary of the sampling media you would use, include the sampling flow rate, discuss how long you would sample, and explain how you would calibrate the sampling train. Include a discussion about why you selected the specific sampling and analytical method.<\/p>\n
Your response to Part 2 should be at least one page in length.
\nPart 3:
\nAccess the attached sampling results here. For each set of results, perform the following actions:<\/p>\n
Calculate the 8-hour time weighted average (TWA) exposure.
\nCompare the results to the appropriate OSHA permissible exposure limit (PEL). Determine which results exceed an established OSHA PEL.<\/p>\n
Write a one-page summary of the sampling results; document the exposures that exceeded an OSHA PEL, and identify those areas that you believe will require the application of controls to reduce risk. Include your calculations, include a list of the OSHA PELs you compared the results to, and explain how you decided that an exposure exceeded an OSHA PEL.<\/p>\n
Part 4:<\/p>\n
Using OSHA\u2019s hierarchy of controls, recommend the control methods that you believe would be the most effective for reducing the risks associated with the exposures that exceeded the OSHA PEL above. Explain how you would implement the controls and how you would evaluate the effectiveness of the controls. Also, discuss any interim control methods you would recommend for the facility.<\/p>\n
This section should be at least one page in length.<\/p>\n
Include a reference page and in-text citations for all sources you used in this project, including your textbook, using proper APA format.<\/p>\n
Safety Data Sheet<\/strong><\/p>\n SECTION 1 PRODUCT AND COMPANY IDENTIFICATION<\/strong><\/p>\n Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n Product Use:<\/strong> Metal Working Fluid Transportation Emergency Response<\/strong><\/p>\n CHEMTREC: (800) 555-9300 or (703) 555-3887 SECTION 2 HAZARDS IDENTIFICATION<\/strong><\/p>\n CLASSIFICATION:<\/strong> Not classified as hazardous according to 29 CFR 1910.1200 (2012).<\/p>\n HAZARDS NOT OTHERWISE CLASSIFIED:<\/strong> Not ApplicableSECTION 3 COMPOSITION\/ INFORMATION ON INGREDIENTS<\/strong><\/p>\n _____________________________________________________________________<\/strong><\/p>\n COMPONENTS<\/strong><\/p>\n CAS NUMBER<\/strong><\/p>\n AMOUNT<\/strong><\/p>\n Highly refined mineral oil (C15 – C50)<\/p>\n Mixture<\/p>\n 70 – 99 %weight<\/p>\n Revision Number:<\/strong> 12Revision Date:<\/strong> APRIL 20, 2015<\/p>\n 1 of 8 Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n SDS :<\/strong> 7721<\/p>\n SECTION 4 FIRST AID MEASURES<\/strong><\/p>\n Description of first aid measures<\/strong> Most important symptoms and effects, both acute and delayed<\/strong> Ingestion:<\/strong> Not expected to be harmful if swallowed. DELAYED OR OTHER HEALTH EFFECTS:<\/strong> Not classified SECTION 5 FIRE FIGHTING MEASURES<\/strong><\/p>\n EXTINGUISHING MEDIA:<\/strong> Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.<\/p>\n PROTECTION OF FIRE FIGHTERS:<\/strong> SECTION 6 ACCIDENTAL RELEASE MEASURES<\/strong><\/p>\n Protective Measures:<\/strong> Eliminate all sources of ignition in vicinity of spilled material. _____________________________________________________________________<\/strong><\/p>\n Revision Number:<\/strong> 12Revision Date:<\/strong> APRIL 20, 2015<\/p>\n 2 of 8 Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n SDS :<\/strong> 7721<\/p>\n precautions in Exposure Controls\/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping. Where feasible and appropriate, remove contaminated soil. Place contaminated materials in disposable containers and dispose of in a manner consistent with applicable regulations. (800) 555-8802 as appropriate or required.SECTION 7 HANDLING AND STORAGE<\/strong><\/p>\n General Handling Information:<\/strong> Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of water. Static Hazard:<\/strong> Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the potential of generating and accumulating an electrostatic charge and\/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.<\/p>\n Container Warnings:<\/strong> Container is not designed to contain pressure. Do not use pressure to empty container or it may rupture with explosive force. Empty containers retain product residue (solid, liquid, and\/or vapor) and can be dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, static electricity, or other sources of ignition. They may explode and cause injury or death. Empty containers should be completely drained, properly closed, and promptly returned to a drum reconditioner or disposed of properly.<\/p>\n SECTION 8 EXPOSURE CONTROLS\/PERSONAL PROTECTION<\/strong><\/p>\n GENERAL CONSIDERATIONS:<\/strong><\/p>\n Consider the potential hazards of this material (see Section 3), applicable exposure limits, job activities, and other substances in the work place when designing engineering controls and selecting personal protective equipment. If engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the personal protective equipment listed below is recommended. The user should read and understand all instructions and limitations supplied with the equipment since protection is usually provided for a limited time or under certain circumstances.<\/p>\n ENGINEERING CONTROLS:<\/strong><\/p>\n Use in a well-ventilated area.<\/p>\n PERSONAL PROTECTIVE EQUIPMENT<\/strong> _____________________________________________________________________<\/strong><\/p>\n Revision Number:<\/strong> 12Revision Date:<\/strong> APRIL 20, 2015<\/p>\n 3 of 8 Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n SDS :<\/strong> 7721<\/p>\n Use a positive pressure air-supplying respirator in circumstances where air-purifying respirators may not provide adequate protection.<\/p>\n Occupational Exposure Limits:<\/strong><\/p>\n Consult local authorities for appropriate values.<\/p>\n SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES<\/strong><\/p>\n Attention: the data below are typical values and do not constitute a specification.<\/strong><\/p>\n Color:<\/strong> Colorless to yellowPhysical State:<\/strong> Liquid Vapor Pressure:<\/strong> <0.01 mmHg Maximum @ 37.8 \u00b0C (100 \u00b0F)Vapor Density (Air = 1):<\/strong> >1 Minimum Melting Point:<\/strong> No data available FLAMMABLE PROPERTIES:<\/strong> Flashpoint:<\/strong> (ASTM D92) 180 \u00b0C (356 \u00b0F) Minimum SECTION 10 STABILITY AND REACTIVITY<\/strong><\/p>\n Reactivity:<\/strong> May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc. Incompatibility With Other Materials:<\/strong> Not applicable _____________________________________________________________________<\/strong><\/p>\n Component<\/strong><\/p>\n Agency<\/strong><\/p>\n TWA<\/strong><\/p>\n STEL<\/strong><\/p>\n Ceiling<\/strong><\/p>\n Notation<\/strong><\/p>\n Highly refined mineral oil (C15 – C50)<\/p>\n OSHA Z-1<\/p>\n 5 mg\/m3<\/p>\n —<\/p>\n —<\/p>\n —<\/p>\n Highly refined mineral oil (C15 – C50)<\/p>\n ACGIH<\/p>\n 5 mg\/m3<\/p>\n 10 mg\/m3<\/p>\n —<\/p>\n —<\/p>\n Revision Number:<\/strong> 12Revision Date:<\/strong> APRIL 20, 2015<\/p>\n 4 of 8 Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n SDS :<\/strong> 7721<\/p>\n Hazardous Polymerization:<\/strong> Hazardous polymerization will not occur.SECTION 11 TOXICOLOGICAL INFORMATION<\/strong><\/p>\n Information on toxicological effects<\/strong> Skin Corrosion\/Irritation:<\/strong> The skin irritation hazard is based on evaluation of data for product components.<\/p>\n Skin Sensitization:<\/strong> The skin sensitization hazard is based on evaluation of data for product components.Acute Dermal Toxicity:<\/strong> The acute dermal toxicity hazard is based on evaluation of data for product<\/p>\n components. Acute Inhalation Toxicity:<\/strong> The acute inhalation toxicity hazard is based on evaluation of data for product components. Germ Cell Mutagenicity:<\/strong> The hazard evaluation is based on data for components or a similar material.<\/p>\n Carcinogenicity:<\/strong> The hazard evaluation is based on data for components or a similar material.<\/p>\n Reproductive Toxicity:<\/strong> The hazard evaluation is based on data for components or a similar material.<\/p>\n Specific Target Organ Toxicity – Single Exposure:<\/strong> The hazard evaluation is based on data for components or a similar material.<\/p>\n Specific Target Organ Toxicity – Repeated Exposure:<\/strong> The hazard evaluation is based on data for components or a similar material.<\/p>\n ADDITIONAL TOXICOLOGY INFORMATION:<\/strong><\/p>\n This product contains petroleum base oils which may be refined by various processes including severe solvent extraction, severe hydrocracking, or severe hydrotreating. None of the oils requires a cancer warning under the OSHA Hazard Communication Standard (29 CFR 1910.1200). These oils have not been listed in the National Toxicology Program (NTP) Annual Report nor have they been classified by the International Agency for Research on Cancer (IARC) as; carcinogenic to humans (Group 1), probably carcinogenic to humans (Group 2A), or possibly carcinogenic to humans (Group 2B).<\/p>\n These oils have not been classified by the American Conference of Governmental Industrial Hygienists (ACGIH) as: confirmed human carcinogen (A1), suspected human carcinogen (A2), or confirmed animal carcinogen with unknown relevance to humans (A3).<\/p>\n SECTION 12 ECOLOGICAL INFORMATION<\/strong><\/p>\n ECOTOXICITY<\/strong><\/p>\n This material is not expected to be harmful to aquatic organisms. _____________________________________________________________________<\/strong><\/p>\n Revision Number:<\/strong> 12Revision Date:<\/strong> APRIL 20, 2015<\/p>\n 5 of 8 Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n SDS :<\/strong> 7721<\/p>\n components.<\/p>\n MOBILITY<\/strong><\/p>\n No data available.<\/p>\n PERSISTENCE AND DEGRADABILITY<\/strong><\/p>\n This material is not expected to be readily biodegradable. The biodegradability of this material is based on an evaluation of data for the components or a similar material. POTENTIAL TO BIOACCUMULATE<\/strong><\/p>\n Bioconcentration Factor: No data available. Octanol\/Water Partition Coefficient: No data available<\/p>\n SECTION 13 DISPOSAL CONSIDERATIONS<\/strong><\/p>\n Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal. Place contaminated materials in containers and dispose of in a manner consistent with applicable regulations. Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.<\/p>\n SECTION 14 TRANSPORT INFORMATION<\/strong><\/p>\n The description shown may not apply to all shipping situations. Consult 49CFR, or appropriate Dangerous Goods Regulations, for additional description requirements (e.g., technical name) and mode-specific or quantity-specific shipping requirements.<\/p>\n DOT Shipping Description:<\/strong> NOT REGULATED AS A HAZARDOUS MATERIAL UNDER 49 CFRIMO\/IMDG Shipping Description:<\/strong> NOT REGULATED AS DANGEROUS GOODS FOR TRANSPORT<\/p>\n UNDER THE IMDG CODE<\/p>\n ICAO\/IATA Shipping Description:<\/strong> NOT REGULATED AS DANGEROUS GOODS FOR TRANSPORT UNDER ICAO<\/p>\n Transport in bulk according to Annex II of MARPOL 73\/78 and the IBC code:<\/strong><\/p>\n Not applicable<\/p>\n SECTION 15 REGULATORY INFORMATION<\/strong><\/p>\n EPCRA 311\/312 CATEGORIES:<\/strong> 1. Immediate (Acute) Health Effects: NO 2. Delayed (Chronic) Health Effects: NO 3. Fire Hazard: NO 4. Sudden Release of Pressure Hazard: NO 5. Reactivity Hazard: NO<\/p>\n _____________________________________________________________________<\/strong><\/p>\n Revision Number:<\/strong> 12Revision Date:<\/strong> APRIL 20, 2015<\/p>\n 6 of 8 Bright-Cut Metalworking Fluid AH, AM, NM<\/strong><\/p>\n SDS :<\/strong> 7721<\/p>\n REGULATORY LISTS SEARCHED:01-1=IARC Group 1 02=NTP Carcinogen<\/p>\n 03=EPCRA 313 04=CA Proposition 65 05=MA RTK No components of this material were found on the regulatory lists above.<\/p>\n CHEMICAL INVENTORIES:<\/strong><\/p>\n All components comply with the following chemical inventory requirements: DSL (Canada), EINECS (European Union), IECSC (China), KECI (Korea), PICCS (Philippines), TSCA (United States).<\/p>\n One or more components does not comply with the following chemical inventory requirements: AICS (Australia), ENCS (Japan).<\/p>\n NEW JERSEY RTK CLASSIFICATION:<\/strong><\/p>\n Under the New Jersey Right-to-Know Act L. 1983 Chapter 315 N.J.S.A. 34:5A-1 et. seq., the product is to be identified as follows: PETROLEUM OIL (Cutting oil)<\/p>\n SECTION 16 OTHER INFORMATION<\/strong><\/p>\n NFPA RATINGS:<\/strong> Health: 0 Flammability: 1 Reactivity: 0<\/p>\n HMIS RATINGS:<\/strong> Health: 1 Flammability: 1 Reactivity: 0 LABEL RECOMMENDATION:<\/strong><\/p>\n Label Category : METALWORKING FLUID 1 – MWF1<\/p>\n
\nProduct Number(s):<\/strong> 233944, 233945, 233946Company Identification<\/strong>
\nAAA Products Company
\na division of AAA U.S.A. Inc.
\n6001 Harvest Rd.
\nAnycity, CA 90000
\nUnited States of America<\/p>\n
\nHealth Emergency<\/strong>
\nAAA Emergency Information Center: Located in the USA. International collect calls accepted. (800)555-0623 or (510) 555-0623
\nProduct Information<\/strong>
\nemail : msds@aaa.com
\nProduct Information: 1 (800) 555-3835, LUBET@aaa.com<\/p>\n
\nEye:<\/strong> No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.
\nSkin:<\/strong> No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
\nIngestion:<\/strong> No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice.
\nInhalation:<\/strong> No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.<\/p>\n
\nIMMEDIATE HEALTH EFFECTS<\/strong>
\nEye:<\/strong> Not expected to cause prolonged or significant eye irritation.
\nSkin:<\/strong> Contact with the skin is not expected to cause prolonged or significant irritation. Contact with the skin is not expected to cause an allergic skin response. Not expected to be harmful to internal organs if absorbed through the skin.<\/p>\n
\nInhalation:<\/strong> Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.<\/p>\n
\nIndication of any immediate medical attention and special treatment needed<\/strong> Not Applicable<\/p>\n
\nFire Fighting Instructions:<\/strong> This material will burn although it is not easily ignited. See Section 7 for proper handling and storage. For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
\nCombustion Products:<\/strong> Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion. Combustion may form oxides of: Sulfur.<\/p>\n
\nSpill Management:<\/strong> Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater. Clean up spill as soon as possible, observing<\/p>\n
\nReporting:<\/strong> Report spills to local authorities and\/or the U.S. Coast Guard’s National Response Center at<\/p>\n
\nPrecautionary Measures:<\/strong> Do not breathe oil mist at concentrations above the recommended mineral oil mist exposure limit.<\/p>\n
\nEye\/Face Protection:<\/strong> No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.
\nSkin Protection:<\/strong> No special protective clothing is normally required. Where splashing is possible, select protective clothing depending on operations conducted, physical requirements and other substances in the workplace. Suggested materials for protective gloves include: 4H (PE\/EVAL), Nitrile Rubber, Silver Shield, Viton.
\nRespiratory Protection:<\/strong> No respiratory protection is normally required.
\nIf user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.<\/p>\n
\nOdor:<\/strong> Petroleum odor
\nOdor Threshold:<\/strong> No data availablepH:<\/strong> Not Applicable<\/p>\n
\nInitial Boiling Point:<\/strong> 315\u00b0C (599\u00b0F) Minimum
\nSolubility:<\/strong> Soluble in hydrocarbons; insoluble in waterFreezing Point:<\/strong> Not Applicable<\/p>\n
\nSpecific Gravity:<\/strong> 0.86 – 0.88 @ 15.6\u00b0C (60.1\u00b0F) \/ 15.6\u00b0C (60.1\u00b0F)Density:<\/strong> 0.87 kg\/l @ 15\u00b0C (59\u00b0F) (Typical)
\nViscosity:<\/strong> 35.2 mm2\/s @ 40\u00b0C (104\u00b0F) Minimum
\nEvaporation Rate:<\/strong> No data available
\nDecomposition temperature:<\/strong> No data available
\nOctanol\/Water Partition Coefficient:<\/strong> No data available<\/p>\n
\nFlammability (solid, gas):<\/strong> No Data Available<\/p>\n
\nAutoignition:<\/strong> No data available
\nFlammability (Explosive) Limits (% by volume in air):<\/strong> Lower: Not Applicable Upper: Not Applicable<\/p>\n
\nChemical Stability:<\/strong> This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.<\/p>\n
\nHazardous Decomposition Products:<\/strong> Hydrogen Sulfide (Elevated temperatures)<\/p>\n
\nSerious Eye Damage\/Irritation:<\/strong> The eye irritation hazard is based on evaluation of data for product components.<\/p>\n
\nAcute Oral Toxicity:<\/strong> The acute oral toxicity hazard is based on evaluation of data for product components.<\/p>\n
\nAcute Toxicity Estimate:<\/strong> Not Determined<\/p>\n
\nThe product has not been tested. The statement has been derived from the properties of the individual<\/p>\n
\nThe product has not been tested. The statement has been derived from the properties of the individual components.<\/p>\n
\n01-2A=IARC Group 2A
\n01-2B=IARC Group 2B<\/p>\n
\n06=NJ RTK
\n07=PA RTK<\/p>\n
\n(0-Least, 1-Slight, 2-Moderate, 3-High, 4-Extreme, PPE:- Personal Protection Equipment Index recommendation, *- Chronic Effect Indicator). These values are obtained using the guidelines or published evaluations prepared by the National Fire Protection Association (NFPA) or the National Paint and Coating Association (for HMIS ratings).<\/p>\n